Tools


Sitemap

Sitemap

Dot

Go for consistent results, efficiently.

MRI - DotGO - Consistency

Consistency.
Quality results for each exam. With the Dot engines.

Dot engines - MRI consistency from head-to-toe.
Dot engines - meet your referrers MRI exam requests.

Apply your clinical MRI standards – everytime.
With the Dot engines your MRI exams are standardized for consistency. Apply your standard to the clinical question at hand (body part, indication) but still stay flexible to adapt quickly. For 88%1 of MRI exams there is a Dot engine available.

 

The Dot engines, standardize your exams – from head-to-toe.

  • Adapt strategies to your patients’ needs
  • Useful automation, less software interaction
  • Intuitive guidance for every exam

 

  • Specific exam views, for the information you need
  • Consistency for every follow-up exam

 

Learn more about the specific Dot engines

MRI - DotGO - Brain Dot Engine - Solution

Flexibility
Exam specific neurological diseases

Consistency
Reproducible positioning and strategy-based protocol adaptation for standardized image quality, faster reading, and more reliable diagnosis

Efficiency
Up to 20% shorter exam-slots2


Features
Consistent exams with Auto Align and BLADE

  • Motion-insensitive scanning
  • Consistent results for follow up examinations
  • Faster and more efficient patient scheduling
  • Same slice positioning across patients and exams
  • AutoAlign for hippocampus – preand post surgery

 

MRI - DotGO - Cardiac Dot Engine - Solution

Flexibility
Consistent and faster planning enable more flexibility in staffing and scheduling

Consistency
Guidance and automation make exams more consistent, and results more reliable and reproducible

Efficiency
Up to 50% more patient throughput - even with stress studies3


Features
Automated planning of all cardiac views with AutoAlign Heart

  • Focus on your patient and not on a complex cardiac protocol
  • Comprehensive heart exam in less than 30 minutes3
  • Up to 50% increase in patient throughput3
  • Motion correction with one click
  • Inline Ventricular function for diagnostic information on the fly

 

MRI - DotGO - Abdomen Dot Engine - Solution

Flexibility
Monitoring of exam progress and synchronized timing enables more comfortable and confident scanning

Consistency
Increased contrast timing accuracy for reproducible results

Efficiency
28% better timing accuracy resulting in less repeated examinations and potentially more throughput4


Features
Optimized Auto Bolus timing for dynamic liver examinations

  • Perform “hassle-free” breath-hold and contrast imaging
  • Get diagnostic information through consistent contrast timing
  • Reduce the risk of unnecessary rescans or additional examinations
  • Perform motion free imaging
  • Use offered MRCP and Diffusion decision points

 

MRI - DotGO - Angio Dot Engine - Solution

Flexibility
Interactive approach to contrast timing, calculated and proposed automatically

Consistency
Standardized timing for each patient, resulting in higher consistency and reproducibility

Efficiency
Enables the possibility to use less contrast medium


Features
Acquire optimally timed contrast images with interactive bolus timing

  • Achieve consistent contrast agent timing with your Angio examination
  • Read and report MR Angio cases performed consistently with optimized kinetic timing
  • Deliver clear answers to your referring physicians

 

MRI - DotGO - Knee Dot Engine - Solution

Flexibility
Choose the strategy according to your patients condition, especially with high bandwidth (WARP5)

Consistency
Faster diagnosis and more accurate follow-ups with AutoAlign Knee

Efficiency
Fast 3D measurement and inline processing of MPRs without the need of post-processing


Features
Consistent positioning and sizing with AutoAlign and AutoCoverage

  • Automatic positioning and sizing of slices and FoV
  • Reduction of metal artifacts with WARP
  • Better soft tissue evaluation in proximity of MR conditional implants
  • Motion-insensitive scanning with BLADE
  • Fast isotropic 3D measurements

 

MRI - DotGO - Spine Dot Engine - Solution

Flexibility
Built-in workflows and alternatives for fast adaptation to patient conditions – also during the exam

Consistency
Consistent positioning independent of spine curvature (eg. scoliosis or kyphosis patients)

Efficiency
Inline Curved Planar Reconstruction automatically reconstructs image to appear in one plane


Features
Automated spine labeling, Inline Curved Planar Reconstruction

  • Reduce workflow steps: automated vertebrae labeling, drop& snap positioning
  • Automatic detection of spine geometry - focus on the diagnosis instead of trying to find the right plane
  • Reduction of metal artifacts with WARP5
  • Consistent positioning independent of spine curvature

 

MRI - DotGO - Breast Dot Engine - Solution

Flexibility
Exam Strategies for lesion and implant evaluation, and intervention

Consistency
Frequency Adjustment Guidance reduces confusion between water, fat, saline and silicone

Efficiency
MPR automatically calculated e.g. for high-resolution delayed VIEWS


Features

  • Don’t miss fatty breast tissue or silicone
  • Proper peak identification leads to reliable image quality
  • AutoCoverage for perfusion and diffusion, get the whole picture
  • Single frequency adjust for 3D VIBE helps saving time
  • Automatic MPR calculation, e.g. for high-res delayed VIEWS
  • Biopsy target coordinates on the Dot display at the scanner

 

MRI - DotGO - Large Joint Dot Engine - Solution

Flexibility
Choose the strategy according to your patients condition, especially with high bandwidth (WARP5)

Consistency
Faster diagnosis and more accurate follow-ups with AutoAlign and AutoCoverage

Efficiency
Fast 3D measurement and inline processing of MPRs without the need of post-processing


Features
Reduce artifacts with WARP exam strategies

  • Confident reduction of artifacts with only a few mouse-clicks.
  • Better soft tissue evaluation in proximity to MR conditional metal implants
  • Motion-insensitive scanning with BLADE
  • Fast isotropic 3D measurements

 

MRI - DotGO - TimCT Angio Dot Engine - Solution

Flexibility
Seamless and robust acquisition with a fast and easy to perform planning workflow

Consistency
Standardized timing for each patient resulting in consistent contrast enhancement

Efficiency
More predictable timing makes scheduling easier


Features

  • Use TimCT for seamless scans of large fields of view
  • Plan multistation examinations in one step
  • Read and report MR Angio cases with one seamless FoV
  • Provide reproducible, excellent images achieved with latest technology to your referring physicians
  • Up to 30% faster acquisition for whole body angio exams6,7

 

MRI - DotGO - TimCT Onco Dot Engine - Solution

Flexibility
Seamless and robust aquisition with a fast and easy to perform planning workflow

Consistency
28% higher timing accuracy for dynamic liver examinations4

Efficiency
Less rescans due to increased timing accuracy


Features

  • Use TimCT for seamless scans of large fields of view
  • No planning of multiple steps and no composing
  • Always scan in isocenter
  • Automization of liver dynamics
  • Integration of in-/opposed phase and Dixon fat/water separation in a single scan
  • Scan thorax, abdomen, and pelvis in less than 30 minutes8

 

1 Evaluation of 2.2 million Siemens MR exams, 2013.

2 University Hospital Essen, GER, Brain Dot Engine Workflow Study.

3 Case Study by: Dr. Russell Bull, Royal Bournemouth Hospital, UK.

4 D.R. Martin. Optimization of Single Injection Liver Arterial Phase Gadolinium Enhanced MRI Using Bolus Track Real-Time Imaging.* Emory University, USA.

5 The MRI restrictions (if any) of the metal implant must be considered prior to patient undergoing MRI exam. MR imaging of patients with metallic implants brings specific risks. However, certain implants are approved by the governing regulatory bodies to be MR conditionally safe. For such implants, the previously mentioned warning may not be applicable. Please contact the implant manufacturer for the specific conditional information. The conditions for MR safety are the responsibility of the implant manufacturer, not of Siemens.

6 TimCT Angio study; European Journal of Radiology 80:537-542 (2011). Case study by Koziel, K. et al.

7 University of Utah, Case Study Brain exam, UT, USA.

8 Case study by: Prof. Schaefer, Dr. Baumann Universitaetsklinikum Freiburg, Germany.

Did this information help you?
Thank you for your response
We detected numbers and/or an '@' symbol in your comment. Are you trying to enter a phone number or email address so that we may contact you, please contact us via our email form instead.

Note: to get a direct personal response, please contact us via our email form.

Thank you